Potřebujeme váš souhlas k využití jednotlivých dat, aby se vám mimo jiné mohly ukazovat informace týkající se vašich zájmů. Souhlas udělíte kliknutím na tlačítko „OK“.
Standard Test Methods for Aromatics in Mineral Spirits by Gas Chromatography (Withdrawn 2021)
Automaticky přeložený název:
Standardní zkušební metody pro aromatických látek v minerálních duchů plynovou chromatografií
NORMA vydána dne 1.6.2012
Označení normy: ASTM D3257-06(2012)
Poznámka: NEPLATNÁ
Datum vydání normy: 1.6.2012
Kód zboží: NS-23039
Počet stran: 8
Přibližná hmotnost: 24 g (0.05 liber)
Země: Americká technická norma
Kategorie: Technické normy ASTM
Keywords:
aromatics in mineral spirits, ethylbenzene in mineral spirits, gas chromatography (GC), mineral spirits, ICS Number Code 87.060.30 (Solvents)
Significance and Use | ||||||||
4.1 These test methods were developed to measure the types and amounts of aromatics in mineral spirits to determine compliance with air pollution regulations that restrict the aromatic content of solvents. They have been demonstrated to be workable and to produce accurate results. However, due to the sensitivity of the tests to operating variables, some laboratories having limited experience with gas chromatographic analyses of hydrocarbons may experience difficulty in performing the tests. |
||||||||
1. Scope | ||||||||
1.1 These test methods cover the determination of ethylbenzene and total eight-carbon (C1.2 It is recognized by analytical chemists that a single column gas chromatography analysis of an unknown sample is risky. In such cases, multiple and different analytical techniques must be used for absolutely positive identification, for example, several different gas chromatography columns, gas chromatography/mass spectrometer, or gas chromatography/infrared, etc. In these test methods the material is known and is clearly defined. 1.3 Oxygenated compounds, if present, may interfere and cause erroneous results. Such oxygenated compounds are not normally present in mineral spirits. 1.4 Three test methods are covered as follows: 1.4.1 Test Method A, measurement of ethylbenzene content, C8 plus higher aromatics (except ethylbenzene), and total aromatics by means of a single packed column gas chromatographic analysis. 1.4.2 Test Method B, measurement of ethylbenzene content by means of a rapid packed column gas chromatographic analysis. 1.4.3 Test Method C, measurement of ethylbenzene content, C8 plus higher aromatics (except ethylbenzene) and total aromatics by means of a capillary column gas chromatographic analysis. 1.5 The values stated in SI units are to be regarded as the standard. The values given in parentheses are for information only. 1.6 For purposes of determining conformance of an observed or a calculated value using this test method to relevant specifications, test result(s) shall be rounded off “to the nearest unit” in the last right-hand digit used in expressing the specification limit, in accordance with the rounding-off method of Practice E29. 1.7 For hazard information and guidance, see the supplier's Material Safety Data Sheet. 1.8 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. |
||||||||
2. Referenced Documents | ||||||||
|
Historická
1.3.2012
Historická
1.6.2012
Historická
1.11.2012
Historická
1.6.2012
Historická
1.6.2009
Historická
1.6.2011
Poslední aktualizace: 07.01.2025 (Počet položek: 2 218 326)
© Copyright 2025 NORMSERVIS s.r.o.