Standard Practice for Standardizing Cotton Fiber Test Results by Use of Calibration Cotton Standards
Přeložit název
NORMA vydána dne 1.1.2021
Označení normy: ASTM D3025-07(2021)
Datum vydání normy: 1.1.2021
Kód zboží: NS-1015300
Počet stran: 3
Přibližná hmotnost: 9 g (0.02 liber)
Země: Americká technická norma
Kategorie: Technické normy ASTM
Keywords:
calibration cotton, cotton ,, ICS Number Code 59.060.10 (Natural fibres)
Significance and Use | ||||||||||||
5.1?The purpose of this practice is to provide guiding principles for the use of reference standard cottons for the standardization of instruments and techniques to obtain reproducible test results (within statistical limits) when the tests are performed on samples of cotton fibers by the same or different operators at the same or different times, both within the same laboratory and in different laboratories. 5.2?Results obtained on cotton fiber tests on the same sample may vary widely due to differences in instruments and operator techniques. Some variation in test result levels can be controlled by the physical adjustment of instruments in accordance with manufacturers' instruction. Instrument adjustments are made only to cause instrument values to coincide with specified calibration points established by the manufacturer. Other variations in cotton fiber test results are caused by differences in technique used in specimen preparation, errors in reading test values from scales, variation in the reference standard, and sampling errors in specimen selection. It is necessary that the mean value of at least four sets of determinations per operator-instrument be used in order to form a sound basis for any adjustment of technique or for the use of correction factors.5.3?In comparing results of different operators and different laboratories, for example, between the purchaser and the seller, it is essential that all results be obtained on replicate specimens. Values obtained on individual samples, as well as on a reference standard are never absolute, but have a normal variation about their mean due to heterogeneity of the sample. Therefore confidence limits of a test value are dependent upon the within laboratory variance for the test and the sampling error. The level of the results in different laboratories will be comparable only to the extent of the use of the same reference standards in both laboratories. 5.4?Any one set of determinations on a reference standard may be within the statistical limits of this reference standard cotton approximately 67 % of the time. The mean of a minimum of four sets of tests, as set out in the specific test procedure, is required to establish a reliable mean value for the determination of the test level. Caution should be exercised in the adjustment of instrument or technique on the basis of preliminary results on the working cotton standard or calibration cotton standard because of the variation within these reference standards. 5.5?When the mean value of the initial test results on a reference standard cotton falls within one unit standard deviation of the established values, testing may be started on samples of cotton fiber to be tested. If the mean value does not fall within one standard deviation unit, recheck the instrument adjustments and test an additional set of test specimens from the reference standard cotton. The mean value of these two sets of determinations, where instrument checks have shown the adjustments (instruments) to be in order, may then be used as a basis for modification of technique, or if correction factors are to be used, the basis for the initiation of testing of unknown samples. Correction factors should be based on determinations made before, during, and at the completion of routine testing. |
||||||||||||
1. Scope | ||||||||||||
1.1?This practice covers the use of reference standard cottons for the standardization of instruments and techniques used to test cotton fibers in various laboratories. 1.2?Standardization may be achieved by application of a correction factor based on the reference standards, or by modification of the technique in use. Note 1:?When reference standards are used to develop
correction factors, or to adjust an operator's technique, no
instrument calibration processes are involved. The term Calibration
is properly used for the application or assignment of permanent
scales or marks to an instrument. Adjustments can be made to
specific instruments and accessories such as orifices, metallic
strips, or cellophane sheets, in order to obtain the prescribed
values with a specific instrument. Since an operator's technique or
the interpretation of a method or procedure is inherently variable,
it cannot be calibrated, that is, assigned a permanent, definite
value. The use of reference standards, however, affords a means for
standardizing techniques and checking the reliability of observed
results.
1.3?This practice recognizes two types of reference standards: (1) calibration cotton standards (see 6.1) and (2) working cotton standards (see 6.2). 1.4?The instructions included in this practice can be used with cotton fibers in any form suitable for testing with the particular instrument to be used. 1.5?The instructions in the practice are applicable to cotton fibers but can also be applied to specific blends of cotton and other fibers, or to other fibers that can be tested with the instruments designed for testing cotton fibers. No information is available, however, to show that test procedures standardized with reference cotton samples are equally reliable with various cotton fiber blends or with other fibers. Note 2:?Standardization procedures covered in this practice
are recommended for use with the following: Test Methods
D1440, D1445, D1447, and D1448.
1.6?This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. 1.7?This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee. |
||||||||||||