Potřebujeme váš souhlas k využití jednotlivých dat, aby se vám mimo jiné mohly ukazovat informace týkající se vašich zájmů. Souhlas udělíte kliknutím na tlačítko „OK“.
Standard Practice for Underground Installation of Thermoplastic Pressure Piping
Automaticky přeložený název:
Standardní praxe pro podzemní instalaci z termoplastického tlakovým potrubím
NORMA vydána dne 1.2.2012
Označení normy: ASTM D2774-12
Poznámka: NEPLATNÁ
Datum vydání normy: 1.2.2012
Kód zboží: NS-21438
Počet stran: 8
Přibližná hmotnost: 24 g (0.05 liber)
Země: Americká technická norma
Kategorie: Technické normy ASTM
Keywords:
buried installation, flexible thermoplastic pipe, pressure-rated pipe, underground installation , Thermoplastic pipe/tube/fittings, Underground installation--water supply/distribution systems, Water supply/distribution systems, ICS Number Code 23.040.20 (Plastic pipes)
Significance and Use | ||||||||||||||
This practice may not apply to products which shall be subject to failure at relatively low strains. For low ductility materials, the installed pipe/soil system shall be sufficiently rigid to prevent pipe deformations which could strain the piping material beyond its safe strain limit. |
||||||||||||||
1. Scope | ||||||||||||||
1.1 This practice governs procedures and references ASTM specifications for underground installation of thermoplastic pressure piping, 63-in. (1372-mm) nominal size and smaller. It is beyond the scope of this practice to describe these procedures in detail since it is recognized that significant differences exist in their implementation depending on kind and type of pipe material, pipe size and wall thickness, soil conditions, and the specific end use. 1.1.1 This practice assumes that over the range of anticipated operating conditions, including maximum external loading and minimum internal pressure, the soil/pipe system will offer sufficient structural stability to resist possible excessive diametrical deformation, or even collapse. In cases, particularly with large diameter thinner-walled pipe, for which the validity of this assumption may be in question, the selection of pipe and recommended installation conditions shall be determined by a qualified engineer. 1.1.2 Specific pipe characteristics and end-use requirements shall dictate addition to, or modification of the procedures stated or referenced herein. 1.2 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. Specific precautionary statements are given in Sections 10 and 11. |
||||||||||||||
2. Referenced Documents | ||||||||||||||
|
Historická
1.11.2012
Historická
1.12.2009
Historická
1.10.2012
Historická
1.8.2014
Historická
1.4.2011
Historická
1.8.2010
Poslední aktualizace: 01.11.2024 (Počet položek: 2 208 817)
© Copyright 2024 NORMSERVIS s.r.o.