Standard Specification for Crosslinked Polyethylene Insulation for Wire and Cable Rated 0 to 2000 V
Automaticky přeložený název:
Standardní specifikace pro síťovaného polyetylenu Izolace drátů a kabelů hodnocené 0-2 tisíc V
NORMA vydána dne 1.1.2012
Označení normy: ASTM D2655-12
Poznámka: NEPLATNÁ
Datum vydání normy: 1.1.2012
Kód zboží: NS-21038
Počet stran: 2
Přibližná hmotnost: 6 g (0.01 liber)
Země: Americká technická norma
Kategorie: Technické normy ASTM
Keywords:
ac voltage, crosslinked polyethylene, dc voltage, heat distortion, hot creep, hot set, insulation resistance, water absorption, weather resistant, Crosslinked electrical insulating materials--specifications, Electrical insulating materials--specifications, Insulated wire and cable--specifications, Polyethylene (PE) electrical insulation--specifications, ICS Number Code 29.035.20 (Plastic and rubber insulating materials)
| 1. Scope | ||||||||||
|
1.1 This specification covers a crosslinked polyethylene insulation for electrical wires and cables in conductor sizes 14 AWG [2.08 mm2] and larger. The base polymer of this insulation consists substantially of polyethylene or a polyethylene copolymer. 1.2 This type of insulation is suitable for continuous use on power cables in wet and dry locations, for voltage ratings not exceeding 2000 V and at conductor temperatures not exceeding 90°C for normal operation. For copper conductors, the insulation can be applied over the uncoated metal. 1.3 Materials covered by this specification are not sunlight and weather resistant unless they are carbon black pigmented or contain an additive system designed for this protection. 1.4 In many instances the insulation cannot be tested unless it has been formed around a conductor. Therefore, tests are done on insulated wire in this standard solely to determine the relevant property of the insulation and not to test the conductor or completed cable. 1.5 Whenever two sets of values are presented, in different units, the values in the first set are the standard, while those in parentheses are for information only. |
||||||||||
| 2. Referenced Documents | ||||||||||
|
Historická
1.6.2013
Historická
1.4.2010
Historická
1.4.2012
Historická
1.11.2013
Historická
1.9.2013
Historická
1.3.2008
Chcete mít jistotu, že používáte pouze platné technické normy?
Nabízíme Vám řešení, které Vám zajistí měsíční přehled o aktuálnosti norem, které používáte.
Chcete vědět více informací? Podívejte se na tuto stránku.
Poslední aktualizace: 06.08.2026 (Počet položek: 2 291 512)
© Copyright 2026 NORMSERVIS s.r.o.