Potřebujeme váš souhlas k využití jednotlivých dat, aby se vám mimo jiné mohly ukazovat informace týkající se vašich zájmů. Souhlas udělíte kliknutím na tlačítko „OK“.
Standard Test Method for Phenols in Water by Gas-Liquid Chromatography (Withdrawn 2021)
Automaticky přeložený název:
Standardní zkušební metoda pro fenolů ve vodě plynové chromatografie
NORMA vydána dne 15.6.2012
Označení normy: ASTM D2580-06(2012)
Poznámka: NEPLATNÁ
Datum vydání normy: 15.6.2012
Kód zboží: NS-20801
Počet stran: 8
Přibližná hmotnost: 24 g (0.05 liber)
Země: Americká technická norma
Kategorie: Technické normy ASTM
Keywords:
chlorophenols, cresols, flame ionization, free fatty acid phase, gas chromatography, ghosts, internal standard, phenolic compounds, ICS Number Code 13.060.50 (Examination of water for chemical substances)
Significance and Use | ||||||||||||||||
Phenolic compounds are sometimes found in surface waters from natural and industrial sources. Chlorination of such waters may produce odoriferous, objectionable tasting chlorophenols. These compounds may include o-chlorophenol, p-chlorophenol, 2,6-dichlorophenol, and 2,4-dichlorophenol. |
||||||||||||||||
1. Scope | ||||||||||||||||
1.1 This test method covers a direct aqueous injection procedure for the gas-liquid chromatographic determination of phenols, cresols, and mono- and di-chlorophenols in water. 1.2 The precision and bias of the test method has been calculated from the results of interlaboratory analyses of three master solutions, each containing phenol, p-cresol, p-chlorophenol, 3,5-dichlorophenol. 1.3 The test method may be applied to waste water or concentrates that contain more than 1 mg/L of phenolic compounds. Therefore, for a comparison with Test Methods D1783, see Appendix X1. 1.4 The analyst should recognize that precision statements provided in 17.1 and 17.2 may not apply to waters of other matrices. 1.5 The values stated in SI units are to be regarded as the standard. The values given in parentheses are provided for information only. 1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. For specific hazard statements, see Note 3."s00005">1.4 The guide is applicable to either packed or capillary column gas chromatography, including wide-bore capillary columns. Because of their greatly enhanced resolution, capillary columns are strongly recommended. 1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. |
||||||||||||||||
2. Referenced Documents | ||||||||||||||||
|
Chcete mít jistotu, že používáte pouze platné technické normy?
Nabízíme Vám řešení, které Vám zajistí měsíční přehled o aktuálnosti norem, které používáte.
Chcete vědět více informací? Podívejte se na tuto stránku.
Poslední aktualizace: 04.11.2024 (Počet položek: 2 209 323)
© Copyright 2024 NORMSERVIS s.r.o.