Potřebujeme váš souhlas k využití jednotlivých dat, aby se vám mimo jiné mohly ukazovat informace týkající se vašich zájmů. Souhlas udělíte kliknutím na tlačítko „OK“.
Standard Test Method for Adequacy of Fusion of Extruded Poly(Vinyl Chloride) (PVC) Pipe and Molded Fittings by Acetone Immersion
Automaticky přeložený název:
Standardní zkušební metoda pro přiměřenosti Fusion z extrudovaného poly (vinyl chloridu ) ( PVC) trubky a profilové, armatura acetonem Immersion
NORMA vydána dne 15.3.1995
Označení normy: ASTM D2152-95(2003)
Poznámka: NEPLATNÁ
Datum vydání normy: 15.3.1995
Kód zboží: NS-19442
Počet stran: 4
Přibližná hmotnost: 12 g (0.03 liber)
Země: Americká technická norma
Kategorie: Technické normy ASTM
Keywords:
acetone, fusion, pipe, poly(vinyl chloride): PVC, ICS Number Code 23.040.20 (Plastic pipes), 23.040.45 (Plastic fittings)
| Significance and Use | ||
|
This test method is applicable only for distinguishing between inadequately fused and adequately fused PVC. The difference between thermally degraded and adequately fused PVC cannot be detected by this test method. Acetone immersion is not a substitute for burst, impact, or other physical or chemical tests on PVC pipe or fittings and it, therefore, shall not be used as the only test specification for purchasing of PVC pipe and fittings. This test only detects inadequate fusion and does not determine the over-all quality of the PVC pipe or fittings. This test method is useful in determining whether inadequate fusion contributed to failure of PVC pipe or fittings in other physical or chemical tests, or in service. This test method is useful in evaluating the adequacy of PVC fusion obtained in process or materials trials. This test method determines adequacy of fusion on a single, relatively small specimen. This test method requires the use of a hazardous reagent which must be properly handled and disposed. Therefore, this test method may not be cost-effective to employ as a routine quality control test. |
||
| 1. Scope | ||
|
1.1 This test method covers the determination of the adequacy of fusion of extruded rigid poly(vinyl chloride) (PVC) pipe and molded fittings as indicated by reaction to immersion in anhydrous acetone. 1.2 The values stated in inch-pound units are to be regarded as the standard except where instruments are calibrated in SI units. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. Specific hazards statements are given in Annex A1. |
||
| 2. Referenced Documents | ||
|
Chcete mít jistotu, že používáte pouze platné technické normy?
Nabízíme Vám řešení, které Vám zajistí měsíční přehled o aktuálnosti norem, které používáte.
Chcete vědět více informací? Podívejte se na tuto stránku.
Poslední aktualizace: 29.07.2026 (Počet položek: 2 290 440)
© Copyright 2026 NORMSERVIS s.r.o.