Standard Test Method for Magnetic Rating of Asbestos Fiber and Asbestos Textiles (Withdrawn 2022)
Přeložit název
NORMA vydána dne 1.6.2017
Označení normy: ASTM D1118/D1118M-95(2017)
Poznámka: NEPLATNÁ
Datum vydání normy: 1.6.2017
Kód zboží: NS-688028
Počet stran: 9
Přibližná hmotnost: 27 g (0.06 liber)
Země: Americká technická norma
Kategorie: Technické normy ASTM
Keywords:
asbestos, magnetic, Mapes, products, rating, test, Turner &, Newall,, ICS Number Code 59.060.30 (Mineral and metal fibres)
Significance and Use | ||||||||||||||||
5.1 This test method for the determination of magnetic rating is considered satisfactory for acceptance testing of commercial shipments of asbestos fibers, papers, felts, yarns, rovings, textile products, rigid sheet products, and granular or powdered products. 5.2 Magnetic rating is one of the measurements used for determining the suitability of an asbestos material for electrical insulation. 5.3 The electrical insulating properties of asbestos materials vary inversely with the magnetic rating. Therefore, a low magnetic iron content is required for good electrical insulating. 5.4 The types of asbestos textiles classified by magnetic rating are described in Specification D2100. |
||||||||||||||||
1. Scope | ||||||||||||||||
1.1 This test method covers the procedure for the determination of the magnetic rating of asbestos fiber and asbestos textile products. This test method is used primarily for testing asbestos insulating materials. 1.2 The values stated in either SI units or inch-pound units are to be regarded separately as standard. The values stated in each system may not be exact equivalents; therefore, each system shall be used independently of the other. Combining values from the two systems may result in non-conformance with the standard. 1.3 Warning—Breathing of asbestos dust is hazardous. Asbestos and asbestos products present demonstrated health risks for users and for those with whom they come into contact. In addition to other precautions, when working with asbestos-cement products, minimize the dust that results. For information on the safe use of chrysoltile asbestos, refer to “Safe Use of Chrysotile Asbestos: A Manual on Preventive and Control Measures.”1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. For specific safety hazard, see . 1.5 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee. |
||||||||||||||||