Potřebujeme váš souhlas k využití jednotlivých dat, aby se vám mimo jiné mohly ukazovat informace týkající se vašich zájmů. Souhlas udělíte kliknutím na tlačítko „OK“.
Standard Specification for Flexible Fibrous Glass Insulation for Metal Buildings
Přeložit název
NORMA vydána dne 1.5.2023
Označení normy: ASTM C991-23
Datum vydání normy: 1.5.2023
Kód zboží: NS-1143345
Počet stran: 3
Přibližná hmotnost: 9 g (0.02 liber)
Země: Americká technická norma
Kategorie: Technické normy ASTM
This specification covers the classification, composition, and physical properties of flexible fibrous glass insulation for use as interior surface of walls and roofs of metal buildings. The basic insulation blanket is designed to be postprocessed by a laminating process that applies an adhesive bonded facing to provide the interior finish and vapor retarder requirements for the building envelope The flexible insulation is furnished into Types I and II. Type I which is a glass processed from the molten state into fibrous form, bonded with a thermosetting resin, and formed into a resilient flexible blanket or batt. Type II is a Type I material supplied with a suitable facing adhered to one surface. The following physical properties of Types I and II materials shall be determined: thermal resistance, surface burning characteristics, combustion characteristics, water vapor sorption, fungi resistance, corrosiveness, odor emission, dimensional tolerances, and humid aging.
Keywords:
faced insulation, metal building, thermal insulation,, ICS Number Code 91.100.60 (Thermal and sound insulating materials)
1. Scope | ||||||||||||||||||||||||||||||||||
1.1?This specification covers the classification, composition, and physical properties of flexible fibrous glass insulation for use in metal building roofs and walls. 1.2?The basic insulation blanket is designed to be post-processed by a laminating process that applies an adhesive bonded facing. 1.3?The thermal values measured in accordance with this specification for both pre-processed and post-processed insulation are for the insulation only and do not include the effects of air-film surface resistance, changes in mean temperature, or compression of insulation at the framing members of the building, through metal conductance of fasteners and other parallel heat-transfer paths due to design or installation techniques. 1.4?The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard. 1.5?This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. 1.6?This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee. |
||||||||||||||||||||||||||||||||||
2. Referenced Documents | ||||||||||||||||||||||||||||||||||
|
Poskytování aktuálních informací o legislativních předpisech vyhlášených ve Sbírce zákonů od roku 1945.
Aktualizace 2x v měsíci !
Chcete vědět více informací? Podívejte se na tuto stránku.
Poslední aktualizace: 22.11.2024 (Počet položek: 2 206 568)
© Copyright 2024 NORMSERVIS s.r.o.