Potřebujeme váš souhlas k využití jednotlivých dat, aby se vám mimo jiné mohly ukazovat informace týkající se vašich zájmů. Souhlas udělíte kliknutím na tlačítko „OK“.
Standard Test Method for Flow of Grout for Preplaced-Aggregate Concrete (Flow Cone Method)
Přeložit název
NORMA vydána dne 1.10.2022
Označení normy: ASTM C939/C939M-22
Datum vydání normy: 1.10.2022
Kód zboží: NS-1089346
Počet stran: 3
Přibližná hmotnost: 9 g (0.02 liber)
Země: Americká technická norma
Kategorie: Technické normy ASTM
Keywords:
flow cone, grout, preplaced-aggregate concrete, time of efflux,, ICS Number Code 91.100.30 (Concrete and concrete products)
Significance and Use | ||||||||||
5.1?This test method is applicable to the determination of the fluidity of various fluid grout mixtures. |
||||||||||
1. Scope | ||||||||||
1.1?This test method covers a procedure, used both in the laboratory and in the field, for determining the time of efflux of a specified volume of fluid hydraulic cement grout through a standardized flow cone and used for preplaced-aggregate (PA) concrete; however, the test method may also be used for other fluid grouts. 1.2?It is for use with neat grout and with grouts containing fine aggregate all passing a 2.36 mm (No. 8) sieve. 1.3?This test method is intended for use with grout having an efflux time of 35 s or less. 1.4?When efflux time exceeds 35 s, flowability is better determined by flow table, found in Test Method C109/C109M, using 5 drops in 3 s. 1.5?The values stated in either SI units or inch-pound units are to be regarded separately as standard. The values stated in each system are not necessarily exact equivalents; therefore, to ensure conformance with the standard, each system shall be used independently of the other, and values from the two systems shall not be combined. Some values have only SI units because the inch-pound equivalents are not used in practice (Note 1). Note 1:?Sieve size is identified by its standard designation
in Specification E11. The
alternative designation given in parentheses is for information
only and does not represent a different standard sieve
size.
1.6?This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. 1.7?This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee. |
||||||||||
2. Referenced Documents | ||||||||||
|
Poslední aktualizace: 22.11.2024 (Počet položek: 2 206 568)
© Copyright 2024 NORMSERVIS s.r.o.