Potřebujeme váš souhlas k využití jednotlivých dat, aby se vám mimo jiné mohly ukazovat informace týkající se vašich zájmů. Souhlas udělíte kliknutím na tlačítko „OK“.
Standard Practice for Testing Concrete Pipe Sewer Lines by Low-Pressure Air Test Method (Metric)
Automaticky přeložený název:
Standardní postup zkoušení betonových trubek kanalizačního potrubí nízké - tlak vzduchu zkušební metody ( metrické)
NORMA vydána dne 10.8.2002
Označení normy: ASTM C924M-02
Poznámka: NEPLATNÁ
Datum vydání normy: 10.8.2002
Kód zboží: NS-15672
Počet stran: 4
Přibližná hmotnost: 12 g (0.03 liber)
Země: Americká technická norma
Kategorie: Technické normy ASTM
Keywords:
concrete, pipe, sewer lines, low-pressure air test, gasketed joints, ICS Number Code 13.060.30 (Sewage water), 23.040.50 (Pipes and fittings of other materials)
| 1. Scope | ||||
|
1.1 This practice covers procedures for testing concrete pipe sewer lines, when using the low-pressure air test method to demonstrate the integrity of the installed material and the construction procedures. This practice is used for testing 100 to 600-mm circular concrete pipe sewer lines utilizing gasketed joints. 1.2 This practice is also be used as a preliminary test to enable the installer to demonstrate the condition of the line prior to backfill. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use (see Section 6, Safety Precautions). 1.4 This practice is the metric companion to Practice C 924. Note 1—The user of this practice is advised that air test criteria presented in this practice are similar to those in general use. The test and criteria have been used widely and successfully in testing smaller diameter pipe, but additional data are required to confirm the safety and applicability or develop criteria for pipe larger than 600 mm in diameter. Larger pipe will be accepted more conveniently by visual inspection and individual joint testing. Note 2—The user of this practice is advised that no correlation has been found between air loss and water leakage. |
||||
| 2. Referenced Documents | ||||
|
Chcete pravidelně odebírat informace o nově vycházejících normách z celého světa a to zcela zdarma?
Přihlašte se k odběru. Vše je velice jednoduché a absolutně ZDARMA.
Na výběr máte vydavatele z celého světa.
Poslední aktualizace: 06.07.2026 (Počet položek: 2 286 164)
© Copyright 2026 NORMSERVIS s.r.o.