Potřebujeme váš souhlas k využití jednotlivých dat, aby se vám mimo jiné mohly ukazovat informace týkající se vašich zájmů. Souhlas udělíte kliknutím na tlačítko „OK“.
Standard Test Method for Effects of Laboratory Accelerated Weathering on Elastomeric Joint Sealants
Automaticky přeložený název:
Standardní zkušební metoda pro účincích laboratoře Urychlené stárnutí na elastomerní těsnících
NORMA vydána dne 1.6.2010
Označení normy: ASTM C793-05(2010)
Poznámka: NEPLATNÁ
Datum vydání normy: 1.6.2010
Kód zboží: NS-15091
Počet stran: 4
Přibližná hmotnost: 12 g (0.03 liber)
Země: Americká technická norma
Kategorie: Technické normy ASTM
Keywords:
accelerated weathering, sealant, ultraviolet, weathering, Accelerated aging/testing--building materials, Accelerated aging/testing--elastomeric sealants, Accelerated weathering--sealants, Joint seals/sealants, Temperature tests--building materials, Ultraviolet (UV) analysis--sealants, Weathering (sealants), ICS Number Code 83.060 (Rubber), 91.100.50 (Binders. Sealing materials)
Significance and Use | ||||||
It is known that solar radiation contributes to the degradation of sealants in exterior building joints. The use of a laboratory accelerated weathering machine with actinic radiation, moisture and heat appears to be a feasible means to give indications of early degradation by the appearance of sealant cracking. However, simulated weather factors in combination with extension may produce more severe degradation than weather factors only. Therefore, the effect of the weathering test is made more sensitive by the addition of the bending of the specimen at cold temperature. |
||||||
1. Scope | ||||||
1.1 This test method covers a laboratory procedure for determining the effects of accelerated weathering on cured-in-place elastomeric joint sealants (single- and multicomponent) for use in building construction. 1.2 The values stated in SI units are to be regarded as the standard. The values in parentheses are for information only. 1.3 The committee with jurisdiction over this standard is not aware of any comparable standards published by other ASTM committees or other organizations. 1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. |
||||||
2. Referenced Documents | ||||||
|
Poslední aktualizace: 04.11.2024 (Počet položek: 2 209 323)
© Copyright 2024 NORMSERVIS s.r.o.