Standard Test Method for Linear Shrinkage and Coefficient of Thermal Expansion of Chemical-Resistant Mortars, Grouts, Monolithic Surfacings, and Polymer Concretes
Automaticky přeložený název:
Standardní zkušební metoda pro Lineární smrštění a koeficient teplotní roztažnosti chemicky odolné malty, zálivky, monolitické Surfacings a polymerbetony
NORMA vydána dne 1.8.2012
Označení normy: ASTM C531-00(2012)
Poznámka: NEPLATNÁ
Datum vydání normy: 1.8.2012
Kód zboží: NS-13882
Počet stran: 3
Přibližná hmotnost: 9 g (0.02 liber)
Země: Americká technická norma
Kategorie: Technické normy ASTM
Keywords:
brick mortars, grouts, linear shrinkage, monolithic surfacings, mortars, polymer concretes, thermal expansion, tile grouts, ICS Number Code 91.100.10 (Cement. Gypsum. Lime. Mortar)
Significance and Use | ||||||
4.1 This test method offers a means of comparing the relative linear shrinkage and coefficient of thermal expansion. 4.1.1 The material to be tested is placed in the mold in a fluid or plastic state. As the material makes a transition to a solid state, it adheres to and captures the end studs. 4.1.2 The linear shrinkage measured is the change in length that occurs after the material is rigid enough and strong enough to move the studs. 4.2 This test method can be used for research purposes to provide information on linear changes taking place in the test materials. Other dimensional changes may occur that do not manifest themselves as changes in length. |
||||||
1. Scope | ||||||
1.1 This test method covers the measurement of the linear shrinkage during setting and curing and the coefficient of thermal expansion of chemical-resistant mortars, grouts, monolithic surfacings, and polymer concretes. 1.2 A bar of square cross-section is cast to a prescribed length in a mold that holds measuring studs that are captured in the ends of the finished casting. 1.2.1 The change in length after curing is measured and used to calculate shrinkage. 1.2.2 The change in length at a
specific elevated temperature is measured and used to calculate the
coefficient of thermal expansion.
1.3 This test method is limited to materials with aggregate size of 0.25 in. (6 mm) or less. 1.4 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard. 1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. |
||||||