Potřebujeme váš souhlas k využití jednotlivých dat, aby se vám mimo jiné mohly ukazovat informace týkající se vašich zájmů. Souhlas udělíte kliknutím na tlačítko „OK“.
Standard Test Method for Effectiveness of Pozzolans or Ground Blast-Furnace Slag in Preventing Excessive Expansion of Concrete Due to the Alkali-Silica Reaction
Automaticky přeložený název:
Standardní zkušební metoda pro účinnosti pucolánů nebo mleté vysokopecní strusky v prevenci nadměrné roztažení betonu Vzhledem k Alkali - Silica Reaction
NORMA vydána dne 1.5.2005
Označení normy: ASTM C441-05
Poznámka: NEPLATNÁ
Datum vydání normy: 1.5.2005
Kód zboží: NS-13403
Počet stran: 3
Přibližná hmotnost: 9 g (0.02 liber)
Země: Americká technická norma
Kategorie: Technické normy ASTM
Keywords:
alkali-silica reaction, concrete, expansion, fly ash, ground blast-furnace slag, mortar, pozzolan, silica fume, ICS Number Code 91.100.30 (Concrete and concrete products)
Significance and Use | ||||||||||||||
This test method may be used as a preliminary or screening test to evaluate the relative effectiveness of a number of different materials being considered for use to prevent excessive expansion due to alkali-silica reaction. This test method may also be used to evaluate materials proposed for use on a particular job to prevent excessive expansion due to alkali-silica reaction, by testing in the quantity and in combination with the cement or cements to be used on the job. This test method does not assess the suitability of pozzolans or slag for use in concrete. These materials should comply with Specification C 618, Specification C 989 or Specification C 1240. |
||||||||||||||
1. Scope | ||||||||||||||
1.1 This test method covers the determination of the effectiveness of pozzolans or slag in preventing the excessive expansion caused by reaction between aggregates and alkalies in portland cement mixtures. The evaluation is based on the expansion developed in mortar bars by a combination of portland cement and a pozzolan or slag, made with reactive aggregates (borosilicate glass), during storage under prescribed conditions of test. 1.2 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. |
||||||||||||||
2. Referenced Documents | ||||||||||||||
|
Poslední aktualizace: 24.11.2024 (Počet položek: 2 206 712)
© Copyright 2024 NORMSERVIS s.r.o.