Potřebujeme váš souhlas k využití jednotlivých dat, aby se vám mimo jiné mohly ukazovat informace týkající se vašich zájmů. Souhlas udělíte kliknutím na tlačítko „OK“.
Standard Specification for Structural Clay Load-Bearing Wall Tile
Automaticky přeložený název:
Standardní specifikace pro Hrubé Clay nosná stěna Tile
NORMA vydána dne 1.6.2010
Označení normy: ASTM C34-10
Poznámka: NEPLATNÁ
Datum vydání normy: 1.6.2010
Kód zboží: NS-13030
Počet stran: 3
Přibližná hmotnost: 9 g (0.02 liber)
Země: Americká technická norma
Kategorie: Technické normy ASTM
Keywords:
clay, load-bearing tile, masonry construction, physical properties, shale, structural wall tile, tile, Building materials/applications--specifications, Clay materials/applications--specifications, Clay products (structural)--tile (specifications), Loadbearing masonry units--specifications, Masonry units--specifications, Physical properties/dimensions/characteristics, Shale, Structural building materials/applications, ICS Number Code 81.080 (Refractories)
| 1. Scope | ||||||
|
1.1 This specification covers structural clay loading-bearing wall tile. Two grades of tile are covered, as follows: 1.1.1 Grade LBX—Suitable for general use in masonry construction and adapted for use in masonry exposed to weathering, provided they meet the durability requirements for Grade SW of Specification C216. 1.1.2 Grade LB—Suitable for general use in masonry where not exposed to frost action, or for use in exposed masonry where protected with a facing of 3 in. (76.2 mm) or more of stone, brick, terra cotta, or other masonry. 1.1.3 If tile having a particular color, texture, or finish are desired, these features shall be specified separately by the purchaser. Note 1—Color of tile varies with the type of clay used and degree of burning; hence, it cannot be taken as indicative of classification until after it has been related to absorption and strength by actual tests. 1.2 The property requirements of this specification apply at the time of purchase. The use of results from testing of tile extracted from masonry structures for determining conformance or non-conformance to the property requirements (Section 3) of this standard is beyond the scope of this specification. 1.3 Tile covered by this specification are manufactured from clay, shale, or similar naturally occurring substances and subjected to a heat treatment at elevated temperatures (firing). The heat treatment must develop sufficient fired bond between the particulate constituents to provide the strength and durability requirements of this specification. (See firing and fired bond in Terminology C1232.) 1.4 The text of this specification references notes and footnotes which provide explanatory material. These notes and footnotes (excluding those in tables and figures) shall not be considered as requirements of the standard. 1.5 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard. |
||||||
| 2. Referenced Documents | ||||||
|
Chcete pravidelně odebírat informace o nově vycházejících normách z celého světa a to zcela zdarma?
Přihlašte se k odběru. Vše je velice jednoduché a absolutně ZDARMA.
Na výběr máte vydavatele z celého světa.
Poslední aktualizace: 24.06.2026 (Počet položek: 2 284 377)
© Copyright 2026 NORMSERVIS s.r.o.