Potřebujeme váš souhlas k využití jednotlivých dat, aby se vám mimo jiné mohly ukazovat informace týkající se vašich zájmů. Souhlas udělíte kliknutím na tlačítko „OK“.
Standard Specification for Sewer and Manhole Brick (Made From Clay or Shale)
Automaticky přeložený název:
Standardní specifikace pro kanalizace a Šachtové Brick (vyrobeno z hlíny nebo břidlice )
NORMA vydána dne 1.6.2009
Označení normy: ASTM C32-09
Poznámka: NEPLATNÁ
Datum vydání normy: 1.6.2009
Kód zboží: NS-12941
Počet stran: 2
Přibližná hmotnost: 6 g (0.01 liber)
Země: Americká technická norma
Kategorie: Technické normy ASTM
Keywords:
brick, clay, drainage structures, industrial waste, manhole brick, physical properties, sewer brick, sewers, shale, storm water, Brick--specifications, Catch basins, Clay materials/applications--specifications, Clay pipe/piping systems--specifications, Clay products (structural)--brick (specifications), Industrial waste treatment--specifications, Manhole materials/applications--specifications, Masonry units--specifications, Physical properties/dimensions/characteristics, Sewer brick, Shale
| 1. Scope | ||||
|
1.1 This specification covers brick intended for use in (1) drainage structures for the conveyance of sewage, industrial wastes, and storm water, and (2) related structures such as manholes and catch basins. 1.1.1 Sewer Brick: 1.1.1.1 Grade SS—Brick intended for use in structures requiring low absorption and resistance to the action of sewage carrying large quantities of abrasive material at velocities exceeding 8 ft (2.4 m)/s. 1.1.1.2 Grade SM—Brick intended for use in structures requiring resistance to the action of sewage carrying abrasive materials at velocities less than 8 ft (2.4 m)/s. 1.1.2 Manhole Brick: 1.1.2.1 Grade MS—Brick intended for use in manholes and catch basins not requiring high degrees of abrasive resistance but where a high and uniform degree of resistance to frost action and disintegration is needed when the brick may be frozen when permeated with water. 1.1.2.2 Grade MM—Brick intended for use in manholes not requiring high degrees of abrasive resistance but where a moderate and nonuniform degree of resistance to frost action and disintegration is needed when the brick may be permeated with water. 1.2 The property requirements of this standard apply at the time of purchase. The use of results from testing of brick extracted from masonry structures for determining conformance or non-conformance to the property requirements (Section 3) of this standard is beyond the scope of this standard. 1.3 Brick covered by this standard are manufactured from clay, shale, or similar naturally occurring substances and subjected to a heat treatment at elevated temperatures (firing). The heat treatment must develop sufficient fired bond between the particulate constituents to provide the strength and durability requirements of this specification. (See firing and fired bond in Terminology C 1232.) 1.4 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard. |
||||
| 2. Referenced Documents | ||||
|
Chcete mít jistotu o platnosti užívaných předpisů?
Nabízíme Vám řešení, abyste mohli používat stále platné (aktuální) legislativní předpisy.
Chcete vědět více informací? Podívejte se na tuto stránku.
Poslední aktualizace: 24.06.2026 (Počet položek: 2 284 377)
© Copyright 2026 NORMSERVIS s.r.o.