Potřebujeme váš souhlas k využití jednotlivých dat, aby se vám mimo jiné mohly ukazovat informace týkající se vašich zájmů. Souhlas udělíte kliknutím na tlačítko „OK“.
Standard Specification for Cold-Weather Admixture Systems
Automaticky přeložený název:
Standardní specifikace pro chladného počasí příměsí Systems
NORMA vydána dne 15.10.2010
Označení normy: ASTM C1622/C1622M-10
Poznámka: NEPLATNÁ
Datum vydání normy: 15.10.2010
Kód zboží: NS-12059
Počet stran: 8
Přibližná hmotnost: 24 g (0.05 liber)
Země: Americká technická norma
Kategorie: Technické normy ASTM
Keywords:
chemical admixture, cold-weather admixture, concrete, performance requirements, Chemical admixtures (for concrete), Cold-weather admixture, Cold-weather concrete, Concrete--specifications, Chemical admixtures, ICS Number Code 91.100.10 (Cement. Gypsum. Lime. Mortar)
1. Scope | ||||||||||||||||||||||||||||||||||||||
1.1 This specification covers cold-weather admixture systems to be added to hydraulic-cement concrete when the temperature of the concrete immediately after placement will be as low as -5.0 °C [23.0 °F] prior to the time of initial set. 1.2 This specification stipulates tests of the cold-weather admixture system with suitable materials as described in 11.1-11.3 or with materials proposed for specific work (See 11.5). Unless otherwise requested by the purchaser, tests shall be made using suitable concreting materials as described in 11.1-11.3. Note 1—Whenever practicable, tests should be made using the concreting materials, the mixture proportions, and batching sequence proposed for the specific work (See 11.5) because the time of setting, compressive strength gain, and other properties may vary. 1.3 This specification provides three levels of testing. 1.3.1 Level 1—During the initial approval stage, proof of compliance with the performance requirements defined in Table 1 demonstrates that the cold-weather admixture system meets the requirements of this specification. Uniformity and equivalence tests (See Section 6) shall be carried out to provide results against which later comparisons can be made. 1.3.2 Level 2—Limited retesting is described in 5.2, 5.2.1, and 5.2.2. Proof of compliance with the requirements of Table 1 demonstrates conformity of the admixture system with the requirements of this specification. 1.3.3 Level 3—For acceptance of a lot or for measuring uniformity within or between lots, when specified by the purchaser, uniformity and equivalence tests (See Section 6) shall be used. 1.4 The values stated in either SI units or inch-pound units are to be regarded separately as standard. Within the text, the inch-pound units are shown in brackets. The values stated in each system may not be exact equivalents; therefore, each system shall be used independently of the other. Combining values from the two systems may result in non-conformance with the standard. 1.5 The text of this standard references notes and footnotes, which provide explanatory material. These notes and footnotes (excluding those in tables and figures) shall not be considered as requirements of the standard. 1.6 The following precautionary caveat pertains to the test methods portion, Sections 11-18, of this specification. This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. WARNINGFresh hydraulic cementitious mixtures are caustic and may cause chemical burns to skin and tissue upon prolonged exposure. |
||||||||||||||||||||||||||||||||||||||
2. Referenced Documents | ||||||||||||||||||||||||||||||||||||||
|
Historická
1.6.2013
Historická
1.11.2007
Historická
1.11.2007
Historická
1.6.2009
Historická
1.1.2008
Historická
1.5.2010
Poslední aktualizace: 22.11.2024 (Počet položek: 2 206 568)