Standard Test Method for Concrete Sanitary Sewer Pipe by Negative (Vacuum) or Positive Air Pressure
Automaticky přeložený název:
Standardní zkušební metoda pro konkrétní sanitární kanalizační potrubí o negativní ( vakuum) nebo tlaku vzduchu Pozitivní
NORMA vydána dne 1.5.2005
Označení normy: ASTM C1618-05
Poznámka: NEPLATNÁ
Datum vydání normy: 1.5.2005
Kód zboží: NS-12036
Počet stran: 3
Přibližná hmotnost: 9 g (0.02 liber)
Země: Americká technická norma
Kategorie: Technické normy ASTM
Keywords:
ICS Number Code 93.030 (External sewerage systems)
| Significance and Use | ||||||||
|
This is a quality control test performed at the manufacturing plant to establish that the finished, shippable pipe meets the leakage limits stated in the specifications. |
||||||||
| 1. Scope | ||||||||
|
1.1 This test method covers procedures for testing of precast concrete pipe sections, prior to delivery, where maximum field leakage rates are specified. 1.2 Tests described in this standard are intended to be used at the point of manufacture of the concrete pipe and are not intended for testing installed pipe (for field tests see Practices C 924, C 969, and C 1214). The user of this specification is advised that individual or multiple pipe sections may be tested for the purpose of testing the pipe barrel and additionally the joints in straight alignment when multiple pipe sections are tested. 1.3 The two leakage rates shown, which were used in calculating the test times, were chosen based on two generally accepted field air and vacuum test criteria. Test times are based on leakage rates and therefore are proportional only to the pipe diameter and are constant for any length of test pipe or pipeline. 1.4 The values stated in inch-pound units are to be regarded as standard. No other units of measurement are included in this standard. Note 1—The availability of this test procedure for concrete pipe varies from location to location. Check with local supplier(s) for availability and recommendations. 1.5 This standard does not purport to address all the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish the appropriate safety and health practices and to determine the applicability of regulatory limitations prior to its use. See Section 6 for specific safety precautions. |
||||||||