Potřebujeme váš souhlas k využití jednotlivých dat, aby se vám mimo jiné mohly ukazovat informace týkající se vašich zájmů. Souhlas udělíte kliknutím na tlačítko „OK“.
Standard Practice for the Determination of 237Np, 232Th, 235U and 238U in Urine by Inductively Coupled Plasma-Mass Spectrometry (ICP-MS) and Gamma Ray Spectrometry. (Withdrawn 2015)
Automaticky přeložený název:
Standardní praktiky pro stanovení 237Np, 232Th, 235U a 238U v moči s indukčně vázanou plazmou, hmotnostní spektrometrie (ICP-MS) a Gamma Ray spektrometrie.
NORMA vydána dne 1.6.2005
Označení normy: ASTM C1614-05(2010)
Poznámka: NEPLATNÁ
Datum vydání normy: 1.6.2005
Kód zboží: NS-12025
Počet stran: 5
Přibližná hmotnost: 15 g (0.03 liber)
Země: Americká technická norma
Kategorie: Technické normy ASTM
Keywords:
Bioassay, urine, neptunium, thorium, uranium, mass, inductively coupled plasma-mass spectrometry, gamma-ray spectrometry, isotope ratio, isotope dilution, extraction chromatography, Bioassay, Extraction chromatography, Gamma-ray spectrometry, ICP-MS (inductively-coupled plasma-mass spectrometry), Neptunium-237, Thorium-232 content, Uranium-235, Urine, ICS Number Code 71.040.50 (Physicochemical methods of analysis)
Significance and Use | ||||||||||
This practice may be used as part of a bioassay program for workers potentially exposed to nuclear material by measuring 237Np, 232Th and 235U and 238U in their urine samples. ICP-MS has been used to analyze for many actinides in high-level radioactive wastes (1)3 , in soils (2) as well as uranium in urine (C 1379). 237Np and 239Pu analysis by ICP-MS in bioassay samples has also been reported (3). Several days counting times are required for alpha-particle analysis of 237Np, 232Th and 235U and 238U whereas ICP-MS requires only four minutes per sample. Alpha-particle counting methods for neptunium may also require the use of 239Pu as a radiotracer for determination of chemical yield. ICP-MS sensitivity limits and isobaric interferences preclude accurate determination of 239Pu, 241Am and 234U at levels present in the urine samples. 234U may be estimated from the 235U:238U ratio by inference. |
||||||||||
1. Scope | ||||||||||
1.1 This practice covers the separation and preconcentration of neptunium-237 (237Np), thorium-232 (232Th), uranium-235 (235U) and uranium-238 (238U) from urine followed by quantitation using ICP-MS. 1.2 This practice can be used to support routine bioassay programs. The minimum detectable concentrations (MDC) for this method, taking the preconcentration factor into account, are approximately 1E-2Bq for 237Np (0.38ng), 2E-6Bq for 232Th (0.50ng), 4E-5Bq for 235U (0.50ng) and 6E-6Bq for 238U (0.48ng). 1.3 This standard does not purport to address all of the safety problems, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. |
||||||||||
2. Referenced Documents | ||||||||||
|
Chcete mít jistotu, že používáte pouze platné technické normy?
Nabízíme Vám řešení, které Vám zajistí měsíční přehled o aktuálnosti norem, které používáte.
Chcete vědět více informací? Podívejte se na tuto stránku.
Poslední aktualizace: 22.11.2024 (Počet položek: 2 206 568)
© Copyright 2024 NORMSERVIS s.r.o.