Potřebujeme váš souhlas k využití jednotlivých dat, aby se vám mimo jiné mohly ukazovat informace týkající se vašich zájmů. Souhlas udělíte kliknutím na tlačítko „OK“.
Standard Guide for Installation of Gypsum Products in Concealed Radiant Ceiling Heating Systems (Includes all amendments And changes 4/14/2014).
Automaticky přeložený název:
Standardní Příručka pro instalaci sádrové výrobky, ve omítku sálavé stropní vytápění Systems
NORMA vydána dne 1.5.2008
Označení normy: ASTM C1546-02(2008)e1
Poznámka: NEPLATNÁ
Datum vydání normy: 1.5.2008
Kód zboží: NS-11777
Počet stran: 3
Přibližná hmotnost: 9 g (0.02 liber)
Země: Americká technická norma
Kategorie: Technické normy ASTM
Keywords:
furring, gypsum panel product, gypsum plaster, heating cable, heating panel, lath, radiant heat, Concealed radiant ceiling heating systems, Gypsum plaster--specifications, Gypsum products--lath, Gypsum products--specifications, Heating panels, Installation--gypsum products, Radiant heat panels, ICS Number Code 91.100.10 (Cement. Gypsum. Lime. Mortar)
| Significance and Use | ||||||
|
The purpose of this guide is to provide information to gypsum product installers for the avoidance of hazards associated with the installation of gypsum products adjacent to, or surrounding, electric heating components and conductors; and to avoid damage to gypsum products when used in conjunction with a concealed radiant heating system. The information given in this guide is applicable to repair of existing cable heating systems and to new construction of radiant heating systems constructed from flexible radiant heating panels. |
||||||
| 1. Scope | ||||||
|
1.1 This guide provides information for trades installing gypsum products in conjunction with a concealed radiant ceiling heating system constructed from thin sheet flexible radiant heating panels, and for the installation of gypsum products after repair of existing concealed radiant ceiling heating systems constructed from heating cable or thin sheet flexible radiant heating panels. 1.2 The values stated in inch-pound units are to be regarded as standard. No other units of measurement are included in this standard. 1.3 This guide does not purport to address any aspect of concealed radiant heating system design or performance, and is limited to the proper installation of gypsum products specified for use in a concealed radiant ceiling heating system. 1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory requirements prior to use. 1.5 The text of this standard references notes and footnotes which provide explanatory material. These notes and footnotes shall not be considered as requirements of the standard. |
||||||
| 2. Referenced Documents | ||||||
|
Poslední aktualizace: 26.05.2026 (Počet položek: 2 280 003)
© Copyright 2026 NORMSERVIS s.r.o.