Potřebujeme váš souhlas k využití jednotlivých dat, aby se vám mimo jiné mohly ukazovat informace týkající se vašich zájmů. Souhlas udělíte kliknutím na tlačítko „OK“.
Standard Specification for Storm Drain Resilient Connectors Between Reinforced Concrete Storm Sewer Structures, Pipes, and Laterals (Metric) (Withdrawn 2020)
Přeložit název
NORMA vydána dne 1.3.2019
Označení normy: ASTM C1478M-19
Poznámka: NEPLATNÁ
Datum vydání normy: 1.3.2019
Kód zboží: NS-939935
Počet stran: 3
Přibližná hmotnost: 9 g (0.02 liber)
Země: Americká technická norma
Kategorie: Technické normy ASTM
Keywords:
design test method, marking, material requirements acceptance criteria, product marking, resilient connector,, ICS Number Code 13.060.30 (Sewage water)
1. Scope | ||||||||||||||||||||||||||||||||
1.1 This specification covers the minimum performance and material requirements for resilient connectors used for connections between precast reinforced concrete storm sewer structures conforming to Specification C478 and pipes, and between precast reinforced concrete pipe and laterals for storm drainage systems. 1.1.1 These connectors are designed to prevent soil migration between the pipe and storm sewer structure, and between the pipe and lateral. 1.2 This specification is the SI companion to C1478. Note 1: This specification covers the design, material, and
performance of the resilient connection only. Connections covered
by this specification are adequate for hydrostatic pressures up to
41 kPa (4.3 m) without leakage when tested in accordance with
Section 7. Infiltration
quantities for an installed system are dependent upon many factors
other than the connections between storm sewer structures and pipe,
and allowable quantities must be covered by other specifications
and suitable testing of the installed pipeline and
system.
Note 2: For installations that exceed 41 kPa (4.3 m), the user
is cautioned to verify the amount of hydrostatic head pressure the
connector will experience. If the total pressure applied to the
connector exceeds the 41 kPa limits of the specification, the user
is advised to contact the connector manufacturer for alternative
methods of connecting the pipe, or applicable alternative
standards.
1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. 1.4 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee. |
||||||||||||||||||||||||||||||||
2. Referenced Documents | ||||||||||||||||||||||||||||||||
|
Chcete mít jistotu, že používáte pouze platné technické normy?
Nabízíme Vám řešení, které Vám zajistí měsíční přehled o aktuálnosti norem, které používáte.
Chcete vědět více informací? Podívejte se na tuto stránku.
Poslední aktualizace: 28.09.2024 (Počet položek: 2 350 600)