Potřebujeme váš souhlas k využití jednotlivých dat, aby se vám mimo jiné mohly ukazovat informace týkající se vašich zájmů. Souhlas udělíte kliknutím na tlačítko „OK“.
Standard Test Method for Determination of Installed Thickness of Pneumatically Applied Loose-Fill Building Insulation
Automaticky přeložený název:
Standardní zkušební metoda pro stanovení Instalovaný Tloušťka pneumaticky aplikované volně sypané izolace budov
NORMA vydána dne 15.4.2014
Označení normy: ASTM C1374-14
Poznámka: NEPLATNÁ
Datum vydání normy: 15.4.2014
Kód zboží: NS-10916
Počet stran: 5
Přibližná hmotnost: 15 g (0.03 liber)
Země: Americká technická norma
Kategorie: Technické normy ASTM
Keywords:
cellulose, cellulosic fiber, fibrous glass, installed thickness, insulation, loose fill, mineral fiber, pneumatically applied, thermal insulation, thickness, ICS Number Code 91.100.60 (Thermal and sound insulating materials), 91.120.10 (Thermal insulation of buildings)
Significance and Use | ||||||||||
5.1 This test method was designed to give the manufacturer of loose-fill insulation products a way of determining what the initial installed thickness should be in a horizontal open attic for pneumatic applications. 5.2 The installed thickness value developed by this test method is intended to provide guidance to the installer in order to achieve a minimum mass/unit area for a given R-value. 5.3 For the purpose of product design, testing should be done at a variety of R-values. At least three R-values should be used: the lowest R-value on the product label, the highest R-value on the product label, and an R-value near the midpoint of the R-value range. 5.4 Specimens are blown in a manner
consistent with the intended installation procedure. Blowing
machine settings should be representative of those typically used
for field application with that machine.
5.5 The material blown for a given 1.1 This test method covers determination of the installed thickness of pneumatically applied loose-fill building insulations prior to settling by simulating an open attic with horizontal blown applications. 1.2 This test method is a laboratory procedure for use by manufacturers of loose-fill insulation for product design, label development, and quality control testing. The apparatus used produces installed thickness results at a given mass/unit area. 1.3 This test method is not the same as the design density procedures described in Test Methods C520 or Specifications C739 or C764. 1.4 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard. 1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. |
||||||||||
2. Referenced Documents | ||||||||||
|
Historická
1.7.2014
Historická
1.5.2014
Historická
1.5.2013
Historická
1.4.2013
Historická
1.3.2014
Historická
1.9.2013
Chcete mít jistotu, že používáte pouze platné technické normy?
Nabízíme Vám řešení, které Vám zajistí měsíční přehled o aktuálnosti norem, které používáte.
Chcete vědět více informací? Podívejte se na tuto stránku.
Poslední aktualizace: 04.11.2024 (Počet položek: 2 209 323)
© Copyright 2024 NORMSERVIS s.r.o.