Standard Test Method for Determination of Slow Crack Growth Parameters of Advanced Ceramics by Constant Stress-Rate Flexural Testing at Ambient Temperature
Automaticky přeložený název:
Standardní zkušební metoda pro stanovení pomalého růstu trhlin Parametry pokročilých keramiky neustálém stresu - Rate ohybu testování při pokojové teplotě
NORMA vydána dne 10.6.2001
Označení normy: ASTM C1368-00
Poznámka: NEPLATNÁ
Datum vydání normy: 10.6.2001
Kód zboží: NS-10883
Počet stran: 9
Přibližná hmotnost: 27 g (0.06 liber)
Země: Americká technická norma
Kategorie: Technické normy ASTM
Keywords:
advanced ceramics, constant stress-rate testing, flexural strength, flexural testing, four-point flexure, slow crack growth, slow crack growth parameters, ICS Number Code 81.060.30 (Advanced ceramics)
| 1. Scope | ||||||||||||||||||||||
|
1.1 This test method covers the determination of slow crack growth (SCG) parameters of advanced ceramics by using constant stress-rate flexural testing in which flexural strength is determined as a function of applied stress rate in a given environment at ambient temperature. The strength degradation exhibited with decreasing applied stress rate in a specified environment is the basis of this test method which enables the evaluation of slow crack growth parameters of a material. Note 1--This test method is frequently referred to as "dynamic fatigue" testing (Refs (1-3)) in which the term" fatigue" is used interchangeably with the term "slow crack growth." To avoid possible confusion with the "fatigue" phenomenon of a material which occurs exclusively under cyclic loading, as defined in Definitions E1150, this test method uses the term "constant stress-rate testing" rather than "dynamic fatigue" testing. Note 2--In glass and ceramics technology, static tests of considerable duration are called "static fatigue" tests, a type of test designated as stress-rupture (See Definitions E1150). 1.2 Values expressed in this test method are in accordance with the International System of Units (SI) and Practice E380. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. |
||||||||||||||||||||||