Potřebujeme váš souhlas k využití jednotlivých dat, aby se vám mimo jiné mohly ukazovat informace týkající se vašich zájmů. Souhlas udělíte kliknutím na tlačítko „OK“.
Standard Test Method for Measuring Ultrasonic Velocity in Advanced Ceramics with Broadband Pulse-Echo Cross-Correlation Method
Automaticky přeložený název:
Standardní zkušební metoda pro měření ultrazvukové rychlost v pokročilé keramiky s Broadband Pulse-Echo korelační metody
NORMA vydána dne 1.8.2012
Označení normy: ASTM C1331-01(2012)
Poznámka: NEPLATNÁ
Datum vydání normy: 1.8.2012
Kód zboží: NS-10729
Počet stran: 7
Přibližná hmotnost: 21 g (0.05 liber)
Země: Americká technická norma
Kategorie: Technické normy ASTM
Keywords:
ceramic composites, material microstructure, materials characterization, monolithic ceramics, nondestructive evaluation, polycrystalline metals, pulse-echo technique, structural composites, ultrasonics, ultrasonic velocity, ICS Number Code 81.060.30 (Advanced ceramics)
Significance and Use | ||||||||||||||
4.1 The velocity measurements described in this test method may be used to characterize material variations that affect mechanical or physical properties. This procedure is useful for measuring variations in microstructural features such as grain structure, pore fractions, and density variations in monolithic ceramics. 4.2 Velocity measurements described herein can assess subtle variations in porosity within a given material or component, as, for example, in ceramic superconductors and structural ceramic specimens (2,3). 4.3 In addition to ceramics and ceramic composites, the velocity measurements described herein may be applied to polycrystalline and single crystal metals, metal matrix composites, and polymer matrix composites. 4.4 An alternative technique for velocity measurement is given in Practice E494. |
||||||||||||||
1. Scope | ||||||||||||||
1.1 This test method describes a procedure for measurement of ultrasonic velocity in structural engineering solids such as monolithic ceramics, toughened ceramics, and ceramic matrix composites. 1.2 This test method is based on the broadband pulse-echo contact ultrasonic method. The procedure involves a computer-implemented, frequency-domain method for precise measurement of time delays between pairs of echoes returned by the back surface of a test sample or part. 1.3 This test method describes a procedure for using a digital cross-correlation algorithm for velocity measurement. The cross-correlation function yields a time delay between any two echo waveforms (1).2 |
||||||||||||||