Potřebujeme váš souhlas k využití jednotlivých dat, aby se vám mimo jiné mohly ukazovat informace týkající se vašich zájmů. Souhlas udělíte kliknutím na tlačítko „OK“.
Standard Test Method for Determination of Impurities in Nuclear Grade Uranium Compounds by Inductively Coupled Plasma Mass Spectrometry
Automaticky přeložený název:
Standardní zkušební metoda pro stanovení nečistot v jaderných uranu sloučenin s indukčně vázanou plazmou hmotnostní spektrometrie
NORMA vydána dne 1.6.2010
Označení normy: ASTM C1287-10
Poznámka: NEPLATNÁ
Datum vydání normy: 1.6.2010
Kód zboží: NS-10484
Počet stran: 10
Přibližná hmotnost: 30 g (0.07 liber)
Země: Americká technická norma
Kategorie: Technické normy ASTM
Keywords:
impurities, inductively coupled plasmamass spectrometry, uranium, uranium dioxide, uranium hexafluoride, uranyl nitrate solutions, uranium oxide, uranium trioxide, ICP-MS (inductively-coupled plasma-mass spectrometry), Impurities--nuclear materials, Mass spectrometry--nuclear materials/applications, Uranium, Uranium oxide (U3O8), ICS Number Code 27.120.30 (Fissile materials and nuclear fuel technology)
1. Scope | ||||||||||||||||||
1.1 This test method covers the determination of 67 elements in uranium dioxide samples and nuclear grade uranium compounds and solutions without matrix separation by inductively coupled plasma mass spectrometry (ICP-MS). The elements are listed in Table 1. These elements can also be determined in uranyl nitrate hexahydrate (UNH), uranium hexafluoride (UF6), triuranium octoxide (U3O8) and uranium trioxide (UO3) if these compounds are treated and converted to the same uranium concentration solution. 1.2 The elements boron, sodium, silicon, phosphorus, potassium, calcium and iron can be determined using different techniques. The analyst's instrumentation will determine which procedure is chosen for the analysis. 1.3 The test method for technetium-99 is given in Annex A1. 1.4 The values stated in SI units are to be regarded as standard. 1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. WarningThe ICP-MS is a source of intense ultra-violet radiation from the radio frequency induced plasma. Protection from radio frequency radiation and UV radiation is provided by the instrument under normal operation. |
||||||||||||||||||
2. Referenced Documents | ||||||||||||||||||
|
Historická
1.11.2011
Historická
1.1.2010
Historická
1.1.2014
Historická
1.6.2011
Historická
1.1.2013
Historická
1.6.2013
Chcete pravidelně odebírat informace o nově vycházejících normách z celého světa a to zcela zdarma?
Přihlašte se k odběru. Vše je velice jednoduché a absolutně ZDARMA.
Na výběr máte vydavatele z celého světa.
Poslední aktualizace: 23.12.2024 (Počet položek: 2 217 157)
© Copyright 2024 NORMSERVIS s.r.o.