Potřebujeme váš souhlas k využití jednotlivých dat, aby se vám mimo jiné mohly ukazovat informace týkající se vašich zájmů. Souhlas udělíte kliknutím na tlačítko „OK“.
Standard Test Method for Concrete Pipe Sewerlines by Negative Air Pressure (Vacuum) Test Method
Automaticky přeložený název:
Standardní zkušební metoda pro betonových trubek Sewerlines od negativního tlaku vzduchu ( Vacuum ) Zkušební metoda
NORMA vydána dne 1.1.2000
Označení normy: ASTM C1214-94(2000)
Poznámka: NEPLATNÁ
Datum vydání normy: 1.1.2000
Kód zboží: NS-10068
Počet stran: 3
Přibližná hmotnost: 9 g (0.02 liber)
Země: Americká technická norma
Kategorie: Technické normy ASTM
Keywords:
concrete pipe, density-concrete, mortar-cement mortar, negative air pressure (vacuum) method, portland cement, pressure testing-concrete pipe, sewerlines, silica, sewerlines (concrete pipe)-negative air pressure (vacuum) method, ICS Number Code 23.040.50 (Pipes and fittings of other materials)
| 1. Scope | ||||||
|
1.1 This test method covers procedures for testing concrete pipe sewerlines, when using the negative air pressure (vacuum) test method to demonstrate the integrity of the installed material and the construction procedures. This test method covers testing of 4 to 36-in. diameter circular concrete pipe sewerlines utilizing gasketed joints. 1.2 Methods described in this test method may also be used as a preliminary test to enable the manufacturer or installer to demonstrate the condition of sewer pipe prior to delivery or backfill. Minimum test times presented in are for pipelines. Holding times for testing an individual pipe may have to be increased to allow for the accumulation of leakage when the tested pipe are incorporated into a continuous pipeline. 1.3 A complete metric companion to Test Method C1214 has been developed-C 1214M; therefore, no metric equivalents are presented in this test method. Note 1--The negative air pressure (vacuum) test criteria presented in this test method are similar to those in general use. The test and criteria have been used widely and successfully in testing smaller diameter pipe. Larger pipe may be accepted more conveniently by visual inspection and individual joint testing.Note 2--It should be understood that no correlation has been found between loss of vacuum and water leakage. 1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. See Section 6 for specific safety precautions. |
||||||
| 2. Referenced Documents | ||||||
|
Poslední aktualizace: 17.05.2026 (Počet položek: 2 278 942)
© Copyright 2026 NORMSERVIS s.r.o.