Potřebujeme váš souhlas k využití jednotlivých dat, aby se vám mimo jiné mohly ukazovat informace týkající se vašich zájmů. Souhlas udělíte kliknutím na tlačítko „OK“.
Standard Test Methods for Physical Testing of Quicklime, Hydrated Lime, and Limestone (Includes all amendments And changes 8/16/2017).
Automaticky přeložený název:
Standardní zkušební metody pro fyzikální zkoušení páleného vápna , vápenného hydrátu , a vápence
NORMA vydána dne 15.11.2005
Označení normy: ASTM C110-05a
Poznámka: NEPLATNÁ
Datum vydání normy: 15.11.2005
Kód zboží: NS-9491
Počet stran: 21
Přibližná hmotnost: 63 g (0.14 liber)
Země: Americká technická norma
Kategorie: Technické normy ASTM
Keywords:
apparent density, dry brightness, dry screening, fineness, lime putty, limestone grindability, particle size, slaking rate
| 1. Scope | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
1.1 These test methods cover physical testing of quicklime and hydrated lime, and of limestone not otherwise covered in ASTM standards.² Note 1—Quicklime and hydrated lime have a high affinity for moisture and carbon dioxide. Caution should be taken to protect both hydrated and quicklime during sampling, storage, and testing (see Practice C 50). 1.2 The test procedures appear in the following order: SectionAir Entrainment Apparent Loose Density of Hydrated Lime, Pulverized Quicklime, and Limestone Apparent Packed Density of Hydrated Lime, Pulverized Quicklime, and Limestone Autoclave Expansion of Hydrated Lime Dry Brightness of Pulverized Limestone Dry Screening by Air Jet Sieve Fineness of Pulverized Quicklime and Hydrated Lime by Air PermeabilityLimestone Grindability Particle Size of Pulverized Limestone Plasticity of Lime Putty Popping and Pitting of Hydrated Lime Residue and Sieve Analysis Settling Rate of Hydrated LimeSlaking Rate of Quicklime Specific Gravity of Hydrated Lime ProductsStandard Consistency of Lime Putty Water Retention of Hydrated Lime Wet Sieve Analysis of Agricultural Liming Materials1.3 The values stated in SI units are to be regarded as the standard. 1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| 2. Referenced Documents | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Chcete mít jistotu, že používáte pouze platné technické normy?
Nabízíme Vám řešení, které Vám zajistí měsíční přehled o aktuálnosti norem, které používáte.
Chcete vědět více informací? Podívejte se na tuto stránku.
Poslední aktualizace: 17.05.2026 (Počet položek: 2 278 942)
© Copyright 2026 NORMSERVIS s.r.o.