Potřebujeme váš souhlas k využití jednotlivých dat, aby se vám mimo jiné mohly ukazovat informace týkající se vašich zájmů. Souhlas udělíte kliknutím na tlačítko „OK“.
Standard Test Method for Temperature of Freshly Mixed Hydraulic-Cement Concrete
Automaticky přeložený název:
Standardní zkušební metody pro teplotu čerstvě smíšené Hydraulické cementárna betonu
NORMA vydána dne 1.7.2008
Označení normy: ASTM C1064/C1064M-08
Poznámka: NEPLATNÁ
Datum vydání normy: 1.7.2008
Kód zboží: NS-9263
Počet stran: 3
Přibližná hmotnost: 9 g (0.02 liber)
Země: Americká technická norma
Kategorie: Technické normy ASTM
Keywords:
freshly mixed concrete, temperature, temperature measuring device, Portland cement concrete (PCC), Ready-mixed concrete, Structural concrete, Temperature tests, ICS Number Code 91.100.10 (Cement. Gypsum. Lime. Mortar), 91.100.30 (Concrete and concrete products)
| Significance and Use | ||||
|
This test method provides a means for measuring the temperature of freshly mixed concrete. The measured temperature represents the temperature at the time of testing and may not be an indication of the temperature of the freshly mixed concrete at a later time. It may be used to verify conformance to a specified requirement for temperature of concrete. Concrete containing aggregate of a nominal maximum size greater than 3 in. [75 mm] may require up to 20 min for the transfer of heat from aggregate to mortar. (See ACI Committee 207.1R Report. ) |
||||
| 1. Scope | ||||
|
1.1 This test method covers the determination of temperature of freshly mixed hydraulic-cement concrete. 1.2 The values stated in either SI or inch-pound units are to be regarded separately as standard. Within the text, SI units are shown in brackets. The values stated in each system may not be exact equivalents; therefore, each system shall be used independently of the other. Combining values from the two systems may result in non-conformance with the standard. 1.3 The text of this standard references notes and footnotes that provide explanatory information. These notes and footnotes (excluding those in tables and figures) shall not be considered as requirements of this standard. 1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. (Warning—Fresh hydraulic cementitious mixtures are caustic and may cause chemical burns to skin and tissue upon prolonged exposure. ) |
||||