Potřebujeme váš souhlas k využití jednotlivých dat, aby se vám mimo jiné mohly ukazovat informace týkající se vašich zájmů. Souhlas udělíte kliknutím na tlačítko „OK“.
Standard Specification for Nickel-Coated, Copper-Clad Steel Wire for Electronic Application (Includes all amendments And changes 8/16/2017).
Automaticky přeložený název:
Standardní specifikace pro poniklované , měděné ocelovým drátem pro Elektronická přihláška
NORMA vydána dne 15.7.1993
Označení normy: ASTM B559-93(2002)e1
Poznámka: NEPLATNÁ
Datum vydání normy: 15.7.1993
Kód zboží: NS-7173
Počet stran: 7
Přibližná hmotnost: 21 g (0.05 liber)
Země: Americká technická norma
Kategorie: Technické normy ASTM
Keywords:
clad steel electrical conductor, copper-clad steel electrical conductor, copper-clad steel wire, electrical conductor, nickel-coated, nickel-electrical/electronic application, ICS Number Code 29.060.10 (Wires)
| 1. Scope | ||||||||||||
|
1.1 This specification covers nickel-coated, round, copper-clad steel wire for electronic application. 1.2 Nickel coatings in mass percentages of the total mass of the coated wire are as follows: 2, 4, 7, 10, and 27 %. Nickel-coated wire having different minimum mass percentages of nickel may be obtained by mutual agreement between the manufacturer and the purchaser. For information purposes, the thickness of coating in microinches provided by the percentages listed above is shown in . 1.3 Four classes of nickel-coated, copper-clad steel wire are covered as follows: 1.3.1 Class N30HS—Nominal 30 % conductivity, hard drawn. 1.3.2 Class N30A—Nominal 30 % conductivity, annealed. 1.3.3 Class N40HS—Nominal 40 % conductivity, hard drawn. 1.3.4 Class N40A—Nominal 40 % conductivity, annealed. 1.4 The values stated in inch-pound units are to be regarded as the standard. The values given in parentheses are for information only, except for resistivity, where the SI units are to be regarded as the standard. 1.5 The following safety hazards caveat pertains only to the test method described in this specification. This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. (Warning—Consideration should be given to toxicity and flammability when selecting solvent cleaners.) |
||||||||||||
| 2. Referenced Documents | ||||||||||||
|
Poslední aktualizace: 11.05.2026 (Počet položek: 2 276 740)
© Copyright 2026 NORMSERVIS s.r.o.