Potřebujeme váš souhlas k využití jednotlivých dat, aby se vám mimo jiné mohly ukazovat informace týkající se vašich zájmů. Souhlas udělíte kliknutím na tlačítko „OK“.
Standard Specification for Straight-Beam Ultrasonic Examination of Plain and Clad Steel Plates for Special Applications
Automaticky přeložený název:
Standardní specifikace pro Straight - Beam ultrazvukem Vyšetření Plain a oděné ocelových plechů pro speciální aplikace
NORMA vydána dne 1.1.2001
Označení normy: ASTM A578/A578M-96(2001)
Poznámka: NEPLATNÁ
Datum vydání normy: 1.1.2001
Kód zboží: NS-3206
Počet stran: 5
Přibližná hmotnost: 15 g (0.03 liber)
Země: Americká technická norma
Kategorie: Technické normy ASTM
Keywords:
nondestructive testing, pressure containing parts, pressure vessel steels, steel plate for pressure vessel applications, steel plates, ultrasonic examinations, ICS Number Code 77.040.20 (Non-destructive testing of metals)
| 1. Scope | ||||||||||
|
1.1 This specification covers the procedure and acceptance standards for straight-beam, pulse-echo, ultrasonic examination of rolled carbon and alloy plain and clad steel plates, 3/8 in. [10 mm] in thickness and over, for special applications. The method will detect internal discontinuities parallel to the rolled surfaces. Three levels of acceptance standards are provided. Supplementary requirements are provided for examination of clad plate and for alternative procedures. 1.2 Individuals performing examinations in accordance with this specification shall be qualified and certified in accordance with the requirements of the latest edition of ASNT SNT-TC-1A or an equivalent accepted standard. An equivalent standard is one which covers the qualification and certification of ultrasonic nondestructive examination candidates and which is acceptable to the purchaser. 1.3 The values stated in either inch-pound units or SI units are to be regarded separately as standard. Within the text, the SI units are shown in brackets. The values stated in each system are not exact equivalents; therefore, each system must be used independently of the other. Combining values from the two systems may result in nonconformance with the specification. 1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. |
||||||||||
| 2. Referenced Documents | ||||||||||
|
Poslední aktualizace: 27.04.2026 (Počet položek: 2 274 955)
© Copyright 2026 NORMSERVIS s.r.o.