API RP 753-ed.2

Management of Hazards Associated with Location of Process Plant Portable Buildings

Přeložit název

NORMA vydána dne 1.1.2024


Jazyk
Provedení
DostupnostSKLADEM
Cena4790.20 bez DPH
4 790.20

Informace o normě:

Označení normy: API RP 753-ed.2
Datum vydání normy: 1.1.2024
Kód zboží: NS-1163309
Počet stran: 66
Přibližná hmotnost: 198 g (0.44 liber)
Země: Americká technická norma
Kategorie: Technické normy API

Anotace textu normy API RP 753-ed.2 :

API RP 753, 2nd Edition, January 2024 - Management of Hazards Associated with Location of Process Plant Portable Buildings

General

This recommended practice (RP) provides guidance for managing the risks from process-related explosion, fire, and toxic material release hazards to personnel located in on-site portable buildings.

The document is based on the API 752 guidance for siting evaluations and the referenced documents concerning its technical aspects. For guidance on the evaluation of each hazard type, the reader should reference API 752. This document provides clarifications and alterations where necessary to address portable buildings.

This RP covers:

  • — new and existing light wood trailers;
  • — new and existing portable buildings (other than light wood trailers) intended to be movable and not intended for perpetual use (intended to be used for the life of the structure or life of the plant) in a specific, fixed location.

Annex B provides examples on the coverage of permanent and portable buildings/tents.

This RP was developed for use at refineries, petrochemical and chemical operations, natural gas liquids extraction plants, natural gas liquefaction plants, and other onshore facilities, such as those covered by the Occupational Safety and Health Administration (OSHA) process safety management regulation, 29 CFR 1910.119 [1].

Non-process-related hazards exist that could present risks to building occupants including, but not limited to, fires originating from within the building, structural collapse due to extreme weather/seismic events, and objects falling on or striking the building. These non-process-related hazards are addressed by building design standards and applicable building codes/regulations, and are not within the scope of this RP.

Guiding Principles

API has established guiding principles for building/tent siting, which are used in API 752, API 753, and API 756. These guiding principles apply to all buildings and tents intended for occupancy:

  • 1) locate personnel away from process areas consistent with safe and effective operations;
  • 2) minimize the use of buildings/tents in close proximity to process areas;
  • 3) manage the occupancy of buildings/tents in close proximity to process areas, especially during periods of planned abnormal operation with increased risk including, but not limited to, unit start-up, testing, or planned shutdown operations;
  • 4) design, construct, install, modify, and maintain buildings/tents to protect occupants from the hazards created by explosion, fire, and toxic material release;
  • 5) manage the use of buildings/tents as an integral part of the design, construction, maintenance, operation, and emergency response of a facility.

These guiding principles reflect the concept of the hierarchy of controls. With respect to building hazards, mitigations arranged in a hierarchy, beginning with the most effective, involve:

  • — eliminating either the occupancy or the hazards;
  • — reducing occupancy or the severity of the hazards;
  • — increasing the distance between the occupants and the hazards;
  • — increasing the resistance of the building to the hazards;
  • — administratively managing the occupancy.

Annex F in API 752, 4th Edition provides a summary of a few select events that clarify, illustrate, and emphasize the lessons learned that led to the development of these guiding principles.

Relationship with API 752 and API 756

New and existing permanent buildings are covered by API 752 [2].

New and existing portable buildings (other than light wood trailers) intended for perpetual use in a specific, fixed location are covered by API 752.

New and existing tents are covered by API 756 [3].

Table B.1 provides examples on the coverage of permanent and portable buildings/tents.

All references in this RP to API 752 and API 756 are to the 4th and 2nd Editions, respectively, which published concurrently with API 753.

Odebírejte informace o nově vydaných normách ZDARMA:

Chcete pravidelně odebírat informace o nově vycházejících normách z celého světa a to zcela zdarma?
Přihlašte se k odběru. Vše je velice jednoduché a absolutně ZDARMA.
Na výběr máte vydavatele z celého světa.




Cookies Cookies

Potřebujeme váš souhlas k využití jednotlivých dat, aby se vám mimo jiné mohly ukazovat informace týkající se vašich zájmů. Souhlas udělíte kliknutím na tlačítko „OK“.

Souhlas můžete odmítnout zde.

Zde máte možnost přizpůsobit si nastavení souborů cookies v souladu s vlastními preferencemi.

Potřebujeme váš souhlas k využití jednotlivých dat, aby se vám mimo jiné mohly ukazovat informace týkající se vašich zájmů.