Potřebujeme váš souhlas k využití jednotlivých dat, aby se vám mimo jiné mohly ukazovat informace týkající se vašich zájmů. Souhlas udělíte kliknutím na tlačítko „OK“.
Standard Specification for Copper and Copper-Alloy Seamless Condenser Tubes and Ferrule Stock (Includes all amendments And changes 12/31/2010).
Automaticky přeložený název:
Standardní specifikace pro mědi a měděných slitin bezešvých trubek kondenzátoru a dutinkou skladě
NORMA vydána dne 1.10.2008
Označení normy: ASTM B111/B111M-08a
Poznámka: NEPLATNÁ
Datum vydání normy: 1.10.2008
Kód zboží: NS-5354
Počet stran: 11
Přibližná hmotnost: 33 g (0.07 liber)
Země: Americká technická norma
Kategorie: Technické normy ASTM
Keywords:
condenser tube, copper, copper alloys, evaporator, ferrule stock, heat exchanger, seamless tube , UNS No. C10100, UNS No. C10200, UNS No. C10300, UNS No. C10800, UNS No. C12000, UNS No. C12200, UNS No. C14200, UNS No. C19200, UNS No. C23000, UNS No. C28000, UNS No. C44300, UNS No. C44400, UNS No. C44500, UNS No. C60800, UNS No. C61300, UNS No. C61400, UNS No. C68700, UNS No. C70400, UNS No. C70600, UNS No. C70620, UNS No. C71000, UNS No. C71500, UNS No. C71520, UNS No. C71640, UNS No. C72200
1. Scope | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
1.1 This specification establishes the
requirements for seamless tube and ferrule stock of copper and
various copper alloys up to
31/8 in. [80 mm] inclusive, in
diameter, for use in surface condensers, evaporators, and heat
exchangers. The following coppers and copper alloys are specified:
(Warning—Mercury is a definite health hazard in use
and disposal. (See 12.1.))
A Designations listed in Classification B 224. 1.2 Units—The values stated in either SI units or inch-pound units are to be regarded separately as standard. The values stated in each system may not be exact equivalents; therefore, each system shall be used independently of the other. Combining values from the two systems may result in non-conformance with the standard. 1.3 The following safety hazards caveat pertains only to the test methods portion, Section 19, of this specification: This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
2. Referenced Documents | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Chcete mít jistotu, že používáte pouze platné technické normy?
Nabízíme Vám řešení, které Vám zajistí měsíční přehled o aktuálnosti norem, které používáte.
Chcete vědět více informací? Podívejte se na tuto stránku.
Poslední aktualizace: 25.04.2024 (Počet položek: 2 896 007)
© Copyright 2024 NORMSERVIS s.r.o.