Luft- und Raumfahrt - Elektrische Leitungen für Luftfahrtverwendung - Prüfverfahren - Teil 417: Feuerbeständigkeit von Leitungen eingebunden in Bündeln
NORMA vydána dne 1.9.2009
Designation standards: ÖNORM EN 3475-417
Publication date standards: 1.9.2009
The number of pages: 8
Approximate weight : 24 g (0.05 lbs)
Country: Austrian technische Norm
Kategorie: Technické normy ÖNORM
This standard specifies a method of testing the fire resistance of fire resistance or fire-proof electrical cables inside a harness. The objective of this test is to qualify these cables when they are confined inside harnesses defined hereafter. Described configurations try to be representative of various cables configuration installed in Aircraft. It shall be used together with EN 3475-100.