Medical electrical equipment - Characteristics of digital X-ray imaging devices - Part 2-1: Determination of dual-energy subtraction efficiency - Detectors used for dual-energy radiographic imaging
NORMA vydána dne 9.8.2023
Designation standards: IEC 62220-2-1-ed.1.0
Publication date standards: 9.8.2023
The number of pages: 43
Approximate weight : 129 g (0.28 lbs)
Country: International technical standard
Kategorie: Technické normy IEC
IEC 62220-2-1:2023 describes the performance metrics associated with DUAL-ENERGY IMAGING capable DIGITAL X-RAY IMAGING DEVICES meant for medical applications and specifies the methods for their determination. These metrics can be used to analyse TISSUE-SUBTRACTED IMAGES and to evaluate dose performance, noise characteristics, and tissue-subtraction efficacy of DIGITAL X-RAY IMAGING DEVICES. The described methods indicate the procedures to obtain MULTI-SPECTRAL PRIMARY DATA and to compute their derived TISSUE-SUBTRACTED IMAGES. The intended users of this document are MANUFACTURERS and well-equipped test laboratories. This document is restricted to DIGITAL X-RAY IMAGING DEVICES that are used for single or multiple exposure dual-energy radiographic imaging based on, for example, CR systems, direct and indirect flat panel-detector based systems. This document excludes and is not applicable to: – DIGITAL X-RAY IMAGING DEVICES intended to be used in mammography or in dental RADIOGRAPHY; – slot scanning DIGITAL X-RAY IMAGING DEVICES; – COMPUTED TOMOGRAPHY or CONE-BEAM COMPUTED TOMOGRAPHY; – photon-energy discriminating devices such as photon counting X-RAY IMAGING DEVICES; – devices for dynamic imaging (where series of images are acquired, as in fluoroscopy or cardiac imaging). – DIGITAL X-RAY IMAGING DEVICES intended to be used with RADIOTHERAPY beams. LIEC 62220-2-1:2023 decrit les mesures normalisees de performances associees aux DISPOSITIFS D’IMAGERIE NUMERIQUE A RAYONNEMENT X capables d’IMAGERIE A DOUBLE ENERGIE destines a des applications medicales, et specifie leur methode de determination. Ces mesures normalisees peuvent etre utilisees pour analyser les IMAGES SOUSTRAITES DES TISSUS et pour evaluer les performances liees a la dose, les caracteristiques sonores et les performances de soustraction des tissus des DISPOSITIFS D’IMAGERIE NUMERIQUE A RAYONNEMENT X. Les methodes decrites indiquent les procedures permettant d’obtenir des DONNEES PRIMAIRES MULTISPECTRALES et de calculer les IMAGES SOUSTRAITES DES TISSUS qui leur sont derivees. Les utilisateurs prevus du present document sont les FABRICANTS et les laboratoires dessai aux equipements modernes. Le present document est limite aux DISPOSITIFS D’IMAGERIE NUMERIQUE A RAYONNEMENT X qui sont utilises dans l’imagerie radiographique a double energie a exposition unique ou multiple fondes, par exemple, sur les systemes CR et les systemes a base de detecteur a panneau plat direct ou indirect. Le present document exclut et ne s’applique pas: – aux DISPOSITIFS D’IMAGERIE NUMERIQUE A RAYONNEMENT X destines a etre utilises en mammographie ou en RADIOGRAPHIE dentaire; – aux DISPOSITIFS D’IMAGERIE NUMERIQUE A RAYONNEMENT X a balayage de fente; – a la TOMODENSITOMETRIE ou a la TOMODENSITOMETRIE A FAISCEAU CONIQUE; – aux dispositifs de discrimination en energie de photon, tels que les DISPOSITIFS D’IMAGERIE A RAYONNEMENT X a comptage de photon; – aux dispositifs d’imagerie dynamique (ou des ensembles d’images sont acquis, comme en radioscopie ou en imagerie cardiaque). – aux DISPOSITIFS D’IMAGERIE NUMERIQUE A RAYONNEMENT X destines a etre utilises avec des faisceaux de RADIOTHERAPIE.