Basic specification for optical amplifier test methods - Part 5-3: Test methods for reflectance parameters - Reflectance tolerance test method using electrical spectrum analyzer
NORMA vydána dne 5.3.2002
Designation standards: IEC 61290-5-3-ed.1.0
Publication date standards: 5.3.2002
The number of pages: 21
Approximate weight : 63 g (0.14 lbs)
Country: International technical standard
Kategorie: Technické normy IEC
Applies to commercial optical fibre amplifiers (OFAs) using active fibres. It establishes requirements for accurate measurements, by means of electrical spectrum analyser test method, of the maximum reflectance tolerable at input and output (as defined in clause 3 of IEC 61291-1). The accuracy for reflectance tolerable is +/-0,5dB. Sapplique auc amplificateurs a fibres optiques (AFO) avec des fibres actives. La norme etablit des prescriptions pour prendre, en utilisant la methode dessai danalyseur spectral electrique, des mesures de la reflectance maximale tolerable a lentree et a la sortie (definis a larticle 3 de la CEI 61291-1). La precision de mesure est de +/- 0,5 dB.