NORMSERVIS s.r.o.

ČSN EN ISO 21013-3 (697248)

Kryogenické nádoby - Část 3: Bezpečnostní příslušenství pro provoz s nízkými teplotami - Stanovení kapacity a dimenzování (Norma k přímému použití jako ČSN).

NORMA vydána dne 1.12.2016

Anglicky -
Tištěné (434.00 CZK)

The information about the standard:

Designation standards: ČSN EN ISO 21013-3
Classification mark: 697248
Catalog number: 500852
Publication date standards: 1.12.2016
The number of pages: 48
Approximate weight : 144 g (0.32 lbs)
Country: Czech technical standard
Kategorie: Technické normy ČSN

Annotation of standard text ČSN EN ISO 21013-3 (697248):

This part of ISO 21013 provides separate calculation methods for determining the required mass flow to be relieved for each of the following specified conditions: - vacuum-insulated vessels with insulation system (outer jacket + insulating material) intact under normal vacuum, outer jacket at ambient temperature, inner vessel at temperature of the contents at the specified relieving pressure; - vacuum-insulated vessels with insulation system (outer jacket + insulating material) intact under normal vacuum, outer jacket at ambient temperature, inner vessel at temperature of the contents at the specified relieving pressure, pressure regulator of the pressure build-up system functioning at full potential; - vacuum or non-vacuum-insulated vessels with insulation system remaining in place, but with loss of vacuum in the case of vacuum-insulated vessels, outer jacket at ambient temperature, inner vessel at temperature of the contents at the specified relieving pressure or vacuum or non-vacuum-insulated vessels with insulation system remaining fully or partially in place, but with loss of vacuum in the case of vacuum-insulated vessels, fire engulfment, inner vessel at temperature of the contents at the specified relieving pressure; - vacuum-insulated vessels containing fluids with saturation temperature below 75 K at 1 bar with insulation system remaining in place, but with loss of vacuum with air or nitrogen in the vacuum space; - vacuum insulated vessels containing fluids with saturation temperature below 75 K at 1 bar with insulation system remaining in place, but with loss of vacuum with air or nitrogen in the vacuum space with fire engulfment; - vessels with insulation system totally lost and fire engulfment. Good engineering practice based on well-established theoretical physical science needs to be adopted to determine the required mass flow where an appropriate calculation method is not provided for an applicable condition