NORMSERVIS s.r.o.

ASTM E580/E580M-24a

Standard Practice for Installation of Ceiling Suspension Systems for Acoustical Tile and Lay-in Panels in Areas Subject to Earthquake Ground Motions (Includes all amendments and changes 10/30/2024).

NORMA vydána dne 1.10.2024

Anglicky -
Online zabezpečené PDF (1703.40 CZK)

Anglicky -
Norma a Redline - Online zabezpečené PDF (2044.00 CZK)

Anglicky -
Tištěné (1703.40 CZK)

Anglicky -
Tisk + redline (2044.00 CZK)


Proč Redline?

Redline představuje rychlý a snadný způsob jak porovnat všechny změny mezi aktuální platnou normou a předchozí verzí.

Díky redline se okamžitě dozvíte o:

Ušetřete si čas i starosti!

Díky Redline již nebudete muset ztrácet čas zjišťováním, co se v nové normě změnilo. Redline Vám ušetří čas a zaručí, že se o změnách v normě dozvíte.

Cena

Pokud si zvolíte možnost "Platná norma + Redline", pak dostanete oba dokumenty! A co je nejlepší, cena Platné normy + Redline je pouze o něco málo vyšší než cena samostatné platné normy.

Zobrazit ukázku Redline

The information about the standard:

Designation standards: ASTM E580/E580M-24a
Publication date standards: 1.10.2024
The number of pages: 11
Approximate weight : 33 g (0.07 lbs)
Country: American technical standard
Kategorie: Technické normy ASTM

Annotation of standard text ASTM E580/E580M-24a :

This practice covers acoustical ceiling suspension systems and their additional requirements for application in areas subject to light to moderate seismic disturbance such as Uniform Building Code Seismic Zone 2, the BOCA Basic National Building Code where Av is less than 0.20 but greater than 0.10, and the Standard Building Code (SBC) where Av is less than 0.20 but greater than 0.05. This practice also covers areas subject to moderate to severe seismic disturbance such as Uniform Building Code Seismic Zones 3 and 4, the BOCA Basic National Building Code where Av is greater than 0.20, and the SBC where Av is greater than 0.20. The application of this practice is to be determined by local authorities. Current seismic maps published by recognized authorities such as those previously mentioned, as well as related material such as Open File 82-1033 and MS-812 Seismicity Maps, should be consulted. This practice is not intended to stifle research and development of new products or methods which may simplify the application method specified herein. A variation, however, must be substantiated by verifiable engineering data. A ceiling area of 144 ft2 [13m2] or less, surrounded by walls that connect directly to the structure above shall be exempt from this practice.


Keywords:
ceiling suspension, earthquake, seismic, seismic restraint, suspended ceiling,, ICS Number Code 91.060.30 (Ceilings. Floors. Stairs)