ASTM C1472-16(2022) - 1.6.2022
 
Significance and Use

4.1?Design professionals, for aesthetic reasons, have desired to limit the spacing and width of sealant joints on exterior walls and other locations of new buildings. Analysis of the performance factors and especially tolerances that affect a sealant joint is necessary to determine if a joint will have durability and be effective in maintaining a seal against the passage of air and water and not experience premature deterioration. If performance factors and tolerances are not understood and included in the design of a sealant joint, then the sealant may reach its durability limit and failure is a distinct possibility.

4.2?Sealant joint failure can result in increased building energy usage due to air infiltration or exfiltration, water infiltration, and deterioration of building systems and materials. Infiltrating water can cause spalling of porous and friable building materials such as concrete, brick, and stone; corrosion of ferrous metals; and decomposition of organic materials, among other effects. Personal injury can result from a fall incurred due to a wetted interior surface as a result of a failed sealant joint. Building indoor air quality can be affected due to organic growth in concealed and damp areas. Deterioration is often difficult and very costly to repair, with the cost of repair work usually greatly exceeding the original cost of the sealant joint work.

4.3?This guide is applicable to sealants with an established movement capacity, in particular elastomeric sealants that meet Specification C920 with a minimum movement capacity rating of ?121/2?%. In general, a sealant with less than ?121/2?% movement capacity can be used with the joint width sizing calculations; however, the width of a joint using such a sealant will generally become too large to be practically considered and installed. It is also applicable to precured sealant extrusions with an established movement capacity that meets Specification C1518.

4.4?The intent of this guide is to describe some of the performance factors and tolerances that are normally considered in sealant joint design. Equations and sample calculations are provided to assist the user of this guide in determining the required width and depth for single and multi-component, liquid-applied sealants when installed in properly prepared joint openings. The user of this guide should be aware that the single largest factor contributing to non-performance of sealant joints that have been designed for movement is poor workmanship. This results in improper installation of sealant and sealant joint components. The success of the methodology described by this guide is predicated on achieving adequate workmanship.

4.5?Joints for new construction can be designed by the recommendations in this guide as well as joints that have reached the end of their service life and need routine maintenance or joints that require remedial work for a failure to perform. Guide C1193 should also be consulted when designing sealant joints. Failure to install a sealant and its components following its guidelines can and frequently will result in failure of a joint design.

4.6?Peer reviewed papers, published in various ASTM Special Technical Publications (STP), provide additional information and examples of sealant joint width calculations that expand on the information described in this guide (2-5). For cases in which the state of the art is such that criteria for a particular condition is not firmly established or there are numerous variables that require consideration, a reference section is provided for further consideration.

4.7?To assist the user of this guide in locating specific information, a detailed listing of guide numbered sections and their headings is included in Appendix X1.

 
1. Scope

1.1?This guide provides information on performance factors such as movement, construction tolerances, and other effects that should be accounted for to properly establish sealant joint size. It also provides procedures to assist in calculating and determining the required width of a sealant joint enabling it to respond properly to those movements and effects. Information in this guide is primarily applicable to single- and multi-component, cold-applied joint sealants and secondarily to precured sealant extrusions when used with properly prepared joint openings and substrate surfaces.

1.2?Although primarily directed towards the understanding and design of sealant joints for walls for buildings and other areas, the information contained herein is also applicable to sealant joints that occur in horizontal slabs and paving systems as well as various sloped building surfaces.

1.3?This guide does not describe the selection and properties of joint sealants (1)2, nor their use and installation, which is described by Guide C1193.

1.4?For protective glazing systems that are designed to resist blast and other effects refer to Guide C1564 in combination with this guide.

1.5?This guide is not applicable to the design of joints sealed with aerosol foam sealants.

1.6?For structural sealant glazing systems refer to Guide C1401 in combination with this guide.

1.7?The values stated in SI units are to be regarded as standard. The values given in parentheses after SI units are provided for information only and are not considered standard. SI units in this guide are in conformance with IEEE/ASTM SI 10-1997.

1.8?The Committee having jurisdiction for this guide is not aware of any comparable standards published by other organizations.

1.9?This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.

1.10?This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

 
2. Referenced Documents

C1523-17

Standard Test Method for Determining Modulus, Tear and Adhesion Properties of Precured Elastomeric Joint Sealants

C1564-20

Standard Guide for Use of Silicone Sealants for Protective Glazing Systems

Manual for Quality Control for Plants and Production of Architectural Precast Concrete Products, MNL-177-77

Volume Changes, and Effects of Movement, Part I,

Technical Notes on Brick Construction, No. 18, Reissued Sept. 2000

IEEE/ASTM SI 10-2002

C1481-12(2017)

Standard Guide for Use of Joint Sealants with Exterior Insulation and Finish Systems (EIFS)

C1518-22

Standard Specification for Precured Elastomeric Silicone Joint Sealants

C1401-23

Standard Guide for Structural Sealant Glazing

C216-23

Standard Specification for Facing Brick (Solid Masonry Units Made from Clay or Shale)

C717-19

Standard Terminology of Building Seals and Sealants

C719-22

Standard Test Method for Adhesion and Cohesion of Elastomeric Joint Sealants Under Cyclic Movement (Hockman Cycle)

C794-18(2022)

Standard Test Method for Adhesion-in-Peel of Elastomeric Joint Sealants

C920-18

Standard Specification for Elastomeric Joint Sealants

C1193-16(2023)

Standard Guide for Use of Joint Sealants